June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING6 - 376“Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com-pleted properly. “Failed” appears next to the failed item on the status display. Turn OFF thepower, and then check the following items. After confirming and cleaning the problems, restartupdating from the beginning.• Is the download jig connected properly?• Is the updating data written to the download jig properly?• Do the download jig and the equipment operate properly?(9) Turn OFF the power, remove the download jig and install the cover plate and the connectorcover.(10) Perform the initialization of the updating data.• Turn ON the power while [0] button and [8] button are pressed simultaneously.• Key in “947”, and then press the [START] button.• Press the [INITIALIZE] button.[B] Confirmation of the updated dataAfter the updating is completed, check each data version in the Setting Mode (08) to confirm that thedata was overwritten properly.08-900: System ROM version08-920: FROM basic section software version08-921: FROM internal program version08-922: UI data fixed section version08-923: UI data common section version08-930: Version of UI data in FROM displayed at power ON08-903: Engine ROM version08-905: Scanner ROM version05/11