June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT3 - 173[E] Image position adjustment of the secondary scanning direction(1) While pressing [0] and [5] simultaneously, turn the power ON. # (Adjustment Mode)(2) Place a ruler on the original glass with its leading edge pushed against the original scale on theleft.(3) Press [FAX] to make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment(Refer to *).*Perform 08-477 and check the value.If the value is 0, use the lower drawer.If the value is 1, use the upper drawer.(4) Measure the distance D from the leading edge of the paper to 10 mm of the copied image of theruler.(5) Check if the distance D is within the range of 10±0.5 mm.(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.(Adjustment Mode) # (Key in the code [305]) # [START]# (Key in a value (acceptable values: 0 to 255))# Press the [ENTER] or the [INTERRUPT] button (stored in memory).# (“100% A” is displayed.)*The larger the adjustment value is, the more the image is shifted to the trailing edge (0.14 mm/step).Fig.3-1510 20 30 40DFeeding directionCopied image of the ruler04/09 PreviousNext |