e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING June 2004 © TOSHIBA TEC5 - 86[2C60] HDD full failure during processingReduce the number of pages of the job in error and perform the job again.Check if the server or local disk has a sufficient space in disk capacity.[2C61] Address Book reading failureTurn the power OFF and then back ON. Perform the job in error again.Reset the data in the Address Book and perform the job again.[2C63] Terminal IP address unsetReset the Terminal IP address.Turn the power OFF and then back ON. Perform the job in error again.[2C64] Terminal mail address unsetReset the Terminal mail address.Turn the power OFF and then back ON. Perform the job in error again.[2C65] SMTP address unsetReset the SMTP address and perform the job.Turn the power OFF and then back ON. Perform the job in error again.[2C66] Server time time-out errorCheck if the SMTP server is operating properly.[2C67] NIC time time-out error[2C68] NIC access error[2C6D] System errorTurn the power OFF and then back ON. Perform the job in error again.If the error still occurs, replace the NIC board.[2C69] SMTP server connection errorReset the login name and password of SMTP server and perform the job again.Check if the SMTP server is operating properly.[2C6A] HOST NAME error (No RFC error)Check if there is an illegal character in the device name.Delete the illegal character and reset the appropriate device name.[2C6B] Terminal mail address errorCheck if there is an illegal character in the Terminal mail address.Delete the illegal character and reset the appropriate Terminal mail address, then perform the jobagain.