e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC2 - 112526 Fuser Pre-running time for firstprinting (OHP film)ALL 0<0-15>M 0: Invalid 1: 0 sec.2: 2 sec. 3: 3 sec.4: 4 sec. 5: 5 sec.6: 6 sec. 7: 7 sec.8: 8 sec. 9: 9 sec.10: 10 sec.11: 12 sec.12: 14 sec.13: 16 sec.14: 18 sec.15: 20 sec.1527-0 Fuser Temperaturedrop switchingtime settingduring printing(Side ther-mistor)The firstdropALL 20<0-200>M This code is valid onlywhen “20” is set to 08-535.Setting value x 5 sec.:from 0 to 1,000 sec.later4527-1 The sec-ond dropALL 30<0-200>M 4527-2 The thirddropALL 48<0-200>M 4527-3 The fourthdropALL 75<0-200>M 4535 Fuser Temperature drop controlsetting during printing(Temperature/Time)ALL 2<0-20>M 0: None1: Pattern 12: Pattern 23: Pattern 34: Pattern 45: Pattern 56: Pattern 67: Pattern 78: Pattern 89: Pattern 910: Pattern 1011: Pattern 1112: Pattern 1213: Pattern 1314: Pattern 1415: Pattern 1516: Pattern 1617: Pattern 1718: Pattern 1819: Pattern 1920: Manual adjustment1536-0 Fuser Temperaturedrop settingduring printing(Center ther-mistor)The firstdropALL 1<0-10>M This code is valid onlywhen “20” is set to 08-535.Setting value x -5°C:from 0°C to -50°C4536-1 The sec-ond dropALL 2<0-10>M 4536-2 The thirddropALL 3<0-10>M 4536-3 The fourthdropALL 3<0-10>M 4537-0 Fuser Temperaturedrop settingduring printing(Side ther-mistor)The firstdropALL 1<0-10>M 4537-1 The sec-ond dropALL 2<0-10>M 4537-2 The thirddropALL 3<0-10>M 4537-3 The fourthdropALL 5<0-10>M 4Setting mode (08) Code Classifi-cation Items Func-tionDefaultablevalue>RAM Contents Proce-dure05/05 PreviousNext |