An automatic relay of information from the PBX when a status change occurs or an alarm is detected.PBXPCSends InformationManagerTRAP ImplementationThe PBX will send the two types of TRAP as follows:Type TRAP Name DescriptionStandard TRAP coldStart Information is sent after turning on the power of the PBXor resetting the PBX.Authentication Failure Information is sent when an unregistered CommunityName and/or Manager IP address is entered.Enterprise SpecificTRAP*1Major Alarm Information is sent when a major alarm is detected.Minor Alarm Information is sent when a minor alarm is detected.*1 Enterprise Specific TRAPs are original KX-NCP-exclusive information (Enterprise Specific MIB)Conditions• Through system programming, it is possible to enable or disable this feature.• Up to 2 SNMP managers can be assigned.• This PBX supports SNMP Protocol Version 1.0 and SNMP Version 1.0-TRAP.• This PBX can only receive read-only MIBs. Write MIBs are not supported.• This PBX supports MIB II.• For more information regarding major and minor alarms, refer to the Installation Manual.• For a list of the MIB object groups supported by this PBX, refer to 21.3 Supported Management InformationBase (MIB) Table in the Appendix.• Through system programming, it is possible to select whether each type of TRAP (e.g., ColdStart) is sentto the SNMP manager or not.Installation Manual References5.1.5 Troubleshooting by Error LogPC Programming Manual References13.4 [11-4-1] SNMP—System Setting13.5 [11-4-2] SNMP—ManagerFeature Manual References10.1.4 Local Alarm InformationDocument Version 2009-12 Feature Manual 29116.1.4 SNMP (Simple Network Management Protocol) System Monitor