Operation Manual – HWPingH3C S3100 Series Ethernet Switches Chapter 1 HWPing Configuration1-331.3.7 TCP Test (Tcpprivate Test) on the Specified PortsI. Network requirementsBoth the HWPing client and the HWPing server are H3C S3100 series Ethernetswitches. Perform a HWPing Tcpprivate test to test time required to establish a TCPconnection between this end (Switch A) and the specified destination end (Switch B),with the port number set to 8000.II. Network diagramFigure 1-8 Network diagram for the Tcpprivate testIII. Configuration procedurez Configure HWPing Server (Switch B):# Enable the HWPing server and configure the IP address and port to listen on. system-view[Sysname] hwping-server enable[Sysname] hwping-server tcpconnect 10.2.2.2 8000z Configure HWPing Client (Switch A):# Enable the HWPing client. system-view[Sysname] hwping-agent enable# Create a HWPing test group, setting the administrator name to "administrator" andtest tag to "tcpprivate".[Sysname] Hwping administrator tcpprivate# Configure the test type as tcpprivate.[Sysname-hwping-administrator-tcpprivate] test-type tcpprivate# Configure the IP address of the HWPing server as 10.2.2.2.[Sysname-hwping-administrator-tcpprivate] destination-ip 10.2.2.2# Configure the destination port on the HWPing server.[Sysname-hwping-administrator-tcpprivate] destination-port 8000# Configure to make 10 probes per test.[Sysname-hwping-administrator-tcpprivate] count 10# Set the probe timeout time to 5 seconds.