3.7 Top Protective CoverDrive models 2A0004 to 2A0081, 4A0002 to 4A0044, and 5A0003 to 5A0032 are designed to IP20/NEMA 1, UL Type 1specifications with a protective cover on the top. Removing this top protective cover or the bottom conduit bracket from anIP20/NEMA 1, UL Type 1 enclosure drive voids the NEMA 1, UL Type 1 protection while maintaining IP20 conformity.u Removing the Top Protective CoverInsert the tip of a straight-edge screwdriver into the small opening located on the front edge of the top protective cover. Gentlyapply pressure as shown in the figure below to free the cover from the drive.Note: Removing the top protective cover or the bottom conduit bracket from an IP20/NEMA 1, UL Type 1 enclosure drive voids the NEMA 1,UL Type 1 protection while maintaining IP20 conformity.Figure 3.25 Removing the Top Protective Coveru Reattaching the Top Protective CoverInsert the two small protruding hooks on the rear side of the top protective cover into the provided mounting holes near theback of the drive, then press down on the front side of the top protective cover to fasten the cover into place.Protective CoverMounting HolesFigure 3.26 Reattaching the Protective Cover3.7 Top Protective Cover82 YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual