H7 ASD Operation Manual 139Accel/Decel Pattern #2Program ⇒ Special Control Parameters ⇒ 1 – #4 SettingsThis parameter enables a user-selected preprogrammed output profile thatcontrols the acceleration and deceleration pattern for the #2 Accel/Decelparameter.Settings:LinearS-Pattern 1S-Pattern 2Direct Access Number — F503Parameter Type — Selection ListFactory Default — LinearChangeable During Run — YesAcc/Dec GroupNo path available (Direct Access Only)While operating using the LED Keypad Option this parameter selects theaccel/decel profile to be used during a multiple-accel/decel profileconfiguration. The accel/decel setting for selections 1 – 4 may be found atF009, F500, F510, and F514, respectively.Note: If using the LCD EOI, press ESC from the Frequency Command screento access this parameter.Direct Access Number — F504Parameter Type — Selection ListFactory Default — 1Changeable During Run — YesAcc/Dec Switching Frequency #1Program ⇒ Special Control Parameters ⇒ Accel/Decel SpecialThis parameter sets the frequency at which the acceleration control is switchedfrom the Accel #1 profile to the Accel #2 profile during a multiple-accelerationprofile configuration.Direct Access Number — F505Parameter Type — NumericalFactory Default — 0.00Changeable During Run — YesMinimum — 0.00Maximum — Max. Freq. (F011)Units — HzS-Pattern Lower Limit AdjustmentProgram ⇒ Special Control Parameters ⇒ Accel/Decel SpecialSets the lower limit of S-pattern 1 and 2.Direct Access Number — F506Parameter Type — NumericalFactory Default — 25.00Changeable During Run — YesMinimum — 0.00Maximum — 50.00Units — %F503 F506www . ElectricalPartManuals . com