3. To activate new selected options, press the "Reset (po)" softkey. A safetyprompt appears.For several options, you will have to also restart SINUMERIK Operate.Corresponding prompts will appear in the user response line.4. Press the "OK" softkey to trigger a warm restart.- OR -Press the "Cancel" softkey to cancel the process.NoteIf you activate the "Set option acc. to license" function, the sum of the axes that can be activatedmay be exceeded. Therefore, reduce the number of actually used axes in the correspondingoptions.Searching for optionsYou have the possibility of finding options using the search function.1. The window "Licensing: All Options" or "Licensing: Non-licensed Options"is open.2. Press the "Search" softkey and enter the required option in the searchform.The cursor is positioned on the first entry that corresponds to the searchterm.3. Press the "Continue search" softkey if the term that was found is not theoption that you were looking for.Additional search optionPress the "Go to beginning" softkey to start the search at the first option.Press the "Go to end" softkey to start the search at the last option.NoteUse of non-licensed optionsBefore licensing options, you can also activate them temporarily without the license keys anduse them for test purposes. In this case, the control displays alarm 8080/8081 periodically,indicating that the option used has not yet been assigned the required license. Further, in thisstate, the NC cannot be started.Licensing4.1 Determining the license requirementSINUMERIK Operate (IM9)Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 75