Attributes Meaning● Block start, type 1 or block end (all program levels, without intermediateblocks)● Block start, type 2 or block end (all program levels, with intermediate blocks)● Block start, type 3 or block end (all main programs, without intermediateblocks)● Block start or block end, block search (all program levels, withoutintermediate blocks)● Geo axis start / direction change (2nd event)● Geo axis stop (2nd event)● Block start, type 2 (2nd event: all program levels, without intermediateblocks)● Block end, type 2 (2nd event: all program levels, with intermediate blocks)● Block start, block advance, type 1 (2nd event)● OEM test event 1 (non-cyclic, block advance)● OEM test event 2 (non-cyclic, main run)● Activate/deactivate synchronized action● Synchronized action initiated (condition fulfilled)● Signaled alarm● Cancel softkey pressed● Program level change● Block end (Interpreter)● Trace end (last event!)● Start trace● WRTPR part program command● WRTPR part program command (block search)● Tool change● Cutting edge change● Tool change (block search)● Cutting edge (block search)● Start trigger initiated● Stop trigger initiated● Block end (block advance)● Block end (2nd event: Block search)● WRTPR part program command (block advance)● Tool change (block advance)● Cutting edge (block advance)Event channel This means that the channel can be defined in SINUMERIK in which a specificevent occurs. For events which are not channel-specific, the field remains emp‐ty.Service and diagnostics18.12 TraceSINUMERIK Operate (IM9)Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 465