14-3Computer Link1414-3 Register settingUse PC register (writing: up to 512 bytes) to provide the IV-S20 with a computer link.Setting item Applicable range of addressWrite register(up to 512 bytes)* Sharp: 09000 to 99776* Mitsubishi: D0000 to D9999* OMRON: DM0000 to DM99990900009001090020900309004090050900609007090100901109012090130901409015:: : :D0000D0001D0002D0003D0004D0005D0006DM0000DM0001DM0002DM0003DM0004DM0005DM0006:: : ::: : :LHLHLHLHLHLHLHLHLHLHLHLHLHLHLHLHLHLHLHLHTermination code (00 (H): normal termination, codesother than 00 (H)abnormal termination - See page 15.3.)Appended information (error code in an error response)Object type number (0 to 15: 00 to 0F (H))Result output (Y0 to Y15)Measurement function 0 using camera 1Measurement function 0 using camera 2Measurement function 1Measurement function 2Measurement function 3Output data from measurement 0 (block 0):Output data from measurement 1 (block 0):Output data from measurement 2 (block 0):Output data from measurement 3 (block 0):Sharp Mitsubishi OMRON Contents*1*3*2*4*5:::1900019001 D0256 LHLHDM0256:: : :::*6Assigned block data*1 to *6 - See the next page.The register map shown above is established when the write start addresses have been set as shownbelow.ManufacturerWrite start addressSharp09000MitsubishiD0000OMRONDM0000Enter the write start address in item 3, WRITE TOP ADDRESS, on the [COMPUTER LINK] menu (page11-19), under the [I/O SETTINGS] menu.Note 1: When a Sharp PC is used, specify an even address for the write start address.Note 2: When 512 bytes are used for the write register in a Sharp PC, use one of the following write startaddresses.09000, 19000, 29000, 39000, 49000, 59000, 69000, 79000, 89000, 99000[Write register map]The write register contains the following data.