9-84Area measurement by binary conversion9Continued on the following pageSelect item 6 MEAS.PROG.COND (conditions for measurement programs).Select item 2 BINARY AREA COND (conditions for binary areas).[TYPE00-MEAS1]1MEAS SELECTION NO CHECK-DEG-OF-MATCHDST&AGL MES. ( GRAY&EDGE GRAV)INSPECT-LEAD MEASR-BIN-AREACNT-BIN-OBJ LABEL-BIN-OBJPOINT MEAS2COMPARE IMAGES NO YES(CAM1)3SELECT CAMERA CAM1 CAM24COPY EXEC TYPE00 MEAS1 NO5INITIALIZATION EXEC6MEAS.PROG. COND (TO NEXT SUB-MENU)7EVALUATION COND (TO NEXT SUB-MENU)8NUMERIC CALC COND (TO NEXT SUB-MENU)9OUTPUT CONDITIONS (TO NEXT SUB-MENU)0UPPER MENU[MEASURING COND] (TYPE00-MEAS.1-MEAS-BIN-AREA)1REGST NO. 00(0~15) REG.NO YES2BINARY AREA COND (TO NEXT SUB-MENU)3UPPER MENU- In item 1, select MEASR-BIN-AREA (measure the area of binary images).- Item 2 will be displayed unless NO is selected in item 8 SELECT CAMERAIMG (camera selection) which is in the [OBJECT TYPE COND] menu.-On the [SYSTEM SETUP menu] move the cursor to 2 OBJECT TYPE COND (conditions ofobject type and press the SET key.-Go to item 0 MEASUREMENT 1, item q MEASUREMENT 2 or, itemw MEASUREMENT 3 on the [OBJECT TYPE COND] menu and press the SET key.This is how the line lookswhen the object type is setto 00 and the selectedmeasurement is 1.- If YES is specified in item 1 REGST NO. (registration number), then item 2 will bedisplayed.Measurement conditions1REGST NO.(registration number)2BINARY AREA COND(conditions for binary areas)3UPPER MENUSetting detailsSet this to any number from 0 to 15 and select NO orYES to store it.The condition for binary areas are set on the next menu.This will return you to the [TYPE00-MEAS1 to 3] menu.[2] Setting detailsAn explanation of item 6 MEAS.PROG.COND (conditions for measurement programs) in the[TYPE00-MEAS1 to 3] menu.