SAMSUNG InstallationDCS-816 February, 19995-25.2 Loop-start Lines5.2.1 Loop-start Lines for 016 Base KSU (Figure 5-1)The DCS-816 system requires MDF connection for analogue trunk (loop-start) lines. Eight(8)analogue trunk lines can be connected to the system if an 8TRK card is installed in the expansionslot. All connections for loop-start lines can be done through the champ connector on the baseboard. See Figure 2-3 and refer to section 2.5 (MDF Cabling).Use one pair twisted wires and connect each loop-start C.O. line to the trunk port you choose viathe champ connector on the base board.CONNECTING LOOP-START LINES FOR 016 BASEKSU FIGURE 5-1CHAMP CONNECTIONPIN COLOUR CIRCUITS/ FUNCTIONS26/ 1 W-BL/ BL-W N.C27/ 2 W-O/ O-W N.C28/ 3 W-GR/ GR-W T/R, 1st Trunk on 8TRK card29/ 4 W-BR/ BR-W T/R, 2nd Trunk on 8TRK card30/ 5 W-S/ S-W T/R, 3rd Trunk on 8TRK card31/ 6 R-BL/ BL-R T/R, 4th Trunk on 8TRK card32/ 7 R-O/ O-R T/R, 5th Trunk on 8TRK card33/ 8 R-GR/ GR-R T/R, 6th Trunk on 8TRK card34/ 9 R-BR/ BR-R T/R, 7th Trunk on 8TRK card35/10R-S/ S-R T/R, 8th Trunk on 8TRK card25 PAIR CABLE WITH FEMALE CONNECTOR TO THE BASE CHAMP CONNECTORPSTN (C.O.)LOOP-START≤ NO POLARITY≤ 8 LOOP-START LINESIF A 8TRK CARD IS INSTALLED.