-34-• Enter a file name and click a radio button.Fix: Uses repeatedly a single file name whenoverwriting new data.Date & Time: Creates and attaches a serialnumber and a date-and-time to theentered file name.• Set a transmission interval.Available time (seconds): 0.2 - 0.9, 1 - 1 440Available time (minutes): 1 - 1 440Notes:• Transmission interval may be delayed depend-ing on the network speed and/or traffic condi-tions.• The alarm image precedes the non-alarmimage in transmission to the FTP server. Thenon-alarm image may not be sent when alarmactivations frequently arise.4. Alarm (FTP) Image Transmission SetupThe alarm setup window specifies the profile of thetransmitting files such as the numbers of files andthe frame rate (fps).• Select ON or OFF to transmit the image files.ON: Transmits the files when an alarm oper-ates.OFF: Does not transmit.• Enter a receiver directory.• Enter a file name.5. Click the SET & REBOOT button.6. Click the Return button to go back to the mainpage.■ User Setup1. Open the User Setup window.2. User Registration• Enter to 16 characters of user name. Thedefault setting is “admin”.• Enter a password. The default setting is ablank.• Enter a password again.• Select an access level, and click the SET but-ton.1 (Administrator): Allows you to operatesetup menus and to view live and record-ed images.2 (Live Only): Allows you to view live andrecorded images.3. User Authentication• Select ON or OFF, and click the SET button.ON: applies the user authentication.OFF: does not apply.• Click the Delete button after selecting anunwanted user name to cancel it.Note: You cannot change admin and level 1that are registered as the default settingswhile the password entry is allowed.