7-157.8 Parameter SettingsSet the initial operation for the positioning unit.1. Select [Set axis] [Parameter settings] in the menu bar, or click the [Parameter setting] iconin the toolbar.2. The parameter setting dialog is shown. Set the parameters.Setting itemsParameter name DescriptionUnit setting The unit to be used for setting each axis.Pulse number per rotation The pulse number per rotation.(It should be cancelled down with the movement amount perrotation.)Movement amount per rotation The movement amount per rotation.(It should be cancelled down with the pulse number perrotation.)Pulse output mode The output method for the pulse- Pulse/Sign method- CW/CCW methodPulse output rotation direction The rotation direction for the pulse outputCW+: + direction is CW.CCW+: + direction is CCW.Limit switch Enable/disable the limit switch.Limit (+) valid logic The logic of the limit switch in “+” directionLimit (-) valid logic The logic of the limit switch in “-“ directionHome valid logic The logic of the home switchNear home valid logic The logic of the near home switchPulse input purpose The purpose of the pulse inputPulse input rotation direction The rotation (CW/CCW) direction for the pulse inputPulse input mode The input method for the pulse inputPulse input transfer multiple The input transfer multiple for the pulse input