17-30Offsetaddress Name Descriptions DefaultvalueSettingrange Unit007H Pulse inputmodeSet the pulse input signal.Set according to the application to be used as the pulse input.Default: 20H008HMoving amountautomatic checkcorrectionnumeratorSet the correction value for the pulse input to be performed when executing themoving amount automatic check.The deviation feedback value (pulse input value after correction) is calculated withthe pulse input value to be input from the pulse input terminal by the followingcalculating formula, and the moving amount automatic check is executed.Deviation feedback value = (Correction numerator / Correction denominator) xPulse inputSetting range: 1 to 32767Default: 1009HMoving amountautomatic checkcorrectiondenominator00AHMoving amountautomatic checkoperaitonSet the operation to be performed when the difference between the commandvalue and feedback value exceeds the moving amount check value.0: Error occurs.If the difference between the feedback value and the command moving amountexceeded the moving amount check value (threshold), an error occurs and theoperation stops.1: Warning occurs.If the difference between the feedback value and the command moving amountexceeded the moving amount check value (threshold), a warning occurs and theoperation continues.2: OffThe moving amount check is not performed.