423. Basic operations3-4-6. Trimming settings1 Press the [FUNC] button to light its indicator, and press the [PinP] button to display the PinP menu.2 Turn [F1] to display the Trim sub menu.Trim Trim Manual5/6 Off Free4:3ManualPair3 Turn [F2] to select the trimming type using the Trim item.Off: No trimming4:3: Automatic trimming so that the aspect ratio is 4:3Manual: Trimming using the value set on the TrimAdj sub menu4 Turn [F3] to select the operation to be performed during the manual setting using the Manual item.Free:The Left, Right, Top and Bottom parameters change independently.However, the Left setting cannot exceed the Right setting (and vice versa) and, similarly, the Topsetting cannot exceed the Bottom setting (and vice versa).Pair: The settings are changed in such a way that the Left and Right trimming amounts and the Top andBottom trimming amount are the same. (This makes for a top-bottom and left-right symmetry.)5 Turn [F1] to display the TrimAdj sub menu, and turn [F2], [F3], [F4] and [F5] to set the trimming values.Operation Parameter Description of setting Setting range Initial valueF2 Left Trimming value at left −50.00 to +50.00 −40.00F3 Top Trimming value at top −50.00 to +50.00 +40.00F4 Bottom Trimming value at bottom −50.00 to +50.00 −40.00F5 Right Trimming value at right −50.00 to +50.00 +40.00 (figure shows the default values)Area trimmedArea where PinP is effectiveOriginal size of PinP0+50-50+500-50TOP (+40)BOTTOM (-40)(-40)LEFT(+40)RIGHT