1006. External interfacesThis unit comes with RS-422, GPI and tally connectors to serve as external interfaces.6-1. RS-422 connectorThis enables the unit to be controlled by an external device.Use it with the settings below. (D-sub 9-pin, female, inch screw)Baud rate: 38400 bpsParity: ODDStop bit: 1 bit123459 8 7 6Pin assignmentPin No. Signal name Description of signal1 FRAME GROUND Frame ground2 TXD – Send data (–)3 RXD + Receive data (+)4 GROUND Ground5 NC Not used6 GROUND Ground7 TXD + Send data (+)8 RXD – Receive data (–)9 FRAME GROUND Frame groundThe following lists the functions which can be controlled by editing controller AG-A850.(Compliant with the GVG protocol)• Crosspoint switch• Wipe pattern selection (BKGD)• Transition mode (MIX/WIPE) selection• Auto transition time setting• Auto transition executionGVG protocol AV-HS400AN GVG protocol AV-HS400AN GVG protocol AV-HS400AN GVG protocol AV-HS400ANA B A B A B A B0 1 WIPE #1 12 13 SQ #1 24 25 SL #1 36 37 3D #11 2 WIPE #2 13 14 SQ #2 25 26 SL #2 37 38 3D #22 3 WIPE #3 14 15 SQ #3 26 27 SL #3 38 39 3D #33 4 WIPE #4 15 16 SQ #4 27 28 SL #4 39 40 3D #44 5 WIPE #5 16 17 SQ #5 28 29 SL #5 40 41 3D #55 6 WIPE #6 17 18 SQ #6 29 30 SL #6 41 42 3D #66 7 WIPE #7 18 19 SQ #7 30 31 SL #7 42 43 3D #77 8 WIPE #8 19 20 SQ #8 31 32 SL #8 43 44 3D #88 9 WIPE #9 20 21 SQ #9 32 33 SL #9 44 45 3D #99 10 WIPE #10 21 22 SQ #10 33 34 — 45 46 3D #1010 11 WIPE #11 22 23 — 34 35 — 46 47 3D #1111 12 WIPE #12 23 24 SQ #12 35 36 — 47 48 3D #12: Set “No. 256” when control is to be exercised from the AG-A850.On the System sub menu of the SYSTEM menu, set On or Off for control from the external device (editor)connected to the RS-422 connector.For details on the settings, see 5-6-2.
PreviousNext Related manuals for Panasonic AVHS400AN - MULTI-FORMAT LIVE SWITCHER This manual is suitable for: |