1-2 BOP HIPWR 031912TABLE 1-2. BOP GENERAL SPECIFICATIONSSPECIFICATION RATING/DESCRIPTION CONDITIONINPUT CHARACTERISTICSa-c voltage nominal 230 Va-c Single phase, or between two phases of a 3-phase systemrange 176 - 264 Va-cFrequency nominal 50/60 Hzrange 47 - 63 HzCurrent 176 Va-c 9.5A (7.5A)* maximum264 Va-c 6.4A (4.4A)* maximumPower factor Source 0.99 minimum nominal output powerSink 0.97 minimumEfficiency 65% (56%)* minimum when sourcingSwitching frequency 70 KHz ±5% (50KHz ±5%)* Active PFC Input for both Source and Recu-peration (Sink)EMC Compliance EN61326-1 (1997) Class A equipmentEMC immunity to: ESD EN61000-4-2 Electrostatic dischargeRadiated RF EN61000-4-3EFT EN61000-4-4 Electrical fast transient/burstSurges EN61000-4-5Conducted RF EN61000-4-6EMC emissions Conducted EN61000-3-2 harmonicsEN61000-3-3 fluctuation & flickerConducted EN55011/CISPR11 0.15 to 30 MHzRadiated EN55011/CISPR11 30 to 1000 MHzLeakage current 3.5 mA 230V a-c, 47-63 HzInsulation coordination Input Installation Category II For TN or TT power systemOvervoltage Category IIOutput Installation Category II Maximum 300V common mode voltagebetween output terminals and chassis ground.Overvoltage Category IIPollution degree 2OUTPUT CHARACTERISTICS **Type of stabilizer Voltage-current, 4-quadrant Switch modeSwitching frequency 100KHz ±5% Output StageSource adjustmentrangevoltage -100% to +100% of rating 0 to 50 deg Ccurrent -100% to +100% of ratingSink adjustment range voltage -100% to +100% of rating 0 to 50°C, recuperated energy is sentback into line for general reusecurrent -100% to +100% of rating* BOP 6-125MG and BOP 10-75MG only.** Output characteristics are for a single standalone unit. Output characteristics of identical multiple unit parallel/series configurationsare described in the Technical Manual associated with the applicable Cable Kit (see Table 1-5).