BOP HIPWR 031912 3-35$. Then highlight a waveform location designated Empty and press $ to save or % to abortthe change and exit. The copied waveform may then be modified and saved with a new name ifdesired (see PAR. 3.3.9.7).3.3.10 RESETCAUTION: PRESSING RESET WILL CAUSE VOLTAGE TRANSIENTS TO APPEAR ATTHE OUTPUT WHICH MAY DAMAGE A CONNECTED LOAD. SWITCH ISRECESSED TO PREVENT INADVERTENT ACTIVATION.Pressing RESET causes the power supply to execute a complete power on sequence to resetthe power supply to the power up settings (see PAR. 3.3.7).3.3.11 OPERATOR TESTINGThe Test System submenu is entered by pressing % from the power-up screen, then highlightRevision/Test and press !. Upon power-up all tests are flagged as Untested. Table 3-13 liststhe tests that can be run. Highlight the choice and press # to run the selected test.TABLE 3-13. REVISIONS/TEST MENUSETTING CHOICES(BOLD = Factory Default) FUNCTIONMAXIMUM OUTPUTVOLTAGE XXCURRENT YY(Cannot be highlighted)XX.0YY.0Displays rated output voltage and current of power supply. including all slavesconnected in parallel or series.TESTDISPLAY Status (see NOTE below) Automatic test, reports status messages (see NOTE below).KEYPAD Status (see NOTE below) Requires depressing keys indicated on LCD.This test requires pressing every key on the keypad, plus moving theADJUST control clockwise and counterclockwise, with the ADJUST controldepressed and released. As the keys and control function pass the tests, thecorresponding function on the LCD is highlighted. When the last test is suc-cessful, the LCD displays “passed.” The test must be completed within twominutes, otherwise a “Failed” indication is displayed.INTER-FACEStatus (see NOTE below) Automatic test, reports status messages (see NOTE below).SERIAL Status (see NOTE below) Automatic test of serial port - requires installation of loop back test connector.(see PAR. 3.5.6.4). Reports status messages (see NOTE below).ANALOG Status (see NOTE below) Automatic test which does not affect unit output. Reports status messages(see NOTE below).OUTPUT Status (see NOTE below) WARNING: DANGEROUS VOLTAGES ARE PRESENT AT THE OUTPUTTERMINALS: DO NOT TOUCH! DISCONNECT LOAD BEFORE RUNNINGTHIS TEST. Output is automatically programmed to + EOnom then – EOnom,then to 0V. Test duration is less than 2 Seconds. Reports status messages(see NOTE below).REVISIONSDISPLAYINTERFACEANALOG(Cannot be highlighted)x.xxy.yyz.zzDisplays current firmware revision for display, interface and analog proces-sors.NOTE: Test status is as follows:UNTESTED Initial status when first entering menu.TESTING Test is running.PASSED Test was successful.FAILED Test failed.FAIL EXT SERIAL test failed - verify loop back connector installed (see PAR. 3.5.6.4).