BOP-1K 031912 B-15B.52 [SOURce:]LIST:COUNt:SKIP COMMAND LIST:COUN:SKIPSyntax: Short Form: LIST:COUN:SKIP nn Long Form: LIST:COUNt:SKIP nnnn = Description: Allows beginning steps of list-generated waveform to be run once, then ignored.When a list is to be repeated using LIST:COUNT, this command allows the user to skip the first nnsteps once the full set has been executed. After the first iteration (which executes all steps), the firstnn steps are skipped. The LIST:COUN:SKIP command allows the user to precondition a list-generatedwaveform by setting unique conditions at the beginning that are not repeated for the rest of the repeti-tions. LIST:CLEar sets nn to 0. Related Commands: LIST:COUN, LIST:COUN:SKIP?, LIST:CLE. (Seeexample, Figure B-5.)B.53 [SOURce:]LIST:COUNt:SKIP? QUERY LIST:COUN:SKIP?Syntax: Short Form: LIST:COUN:SKIP? Long Form: LIST:COUNt:SKIP?Return Value: Description: Identifies how many steps will skipped the first time the list is executed. Returns value set byLIST:COUN:SKIP command. (See example, Figure B-5.)B.54 [SOURce:]LIST:CURRent COMMAND LIST:CURRSyntax: Short Form: LIST:CURR , , . . . (to max of 5900 data points for global dwelltime)Long Form: LIST:CURRent , , . . . (to max of 5900 data points for globaldwell time) = digits with decimal point and Exponent, e.g., 2.71E1 for 27.1Description: Adds the current value (in Amps) to list. This command sequentially adds LIST:CURRent values tothe main channel List Data Table locations illustrated in Table B-2. Starting location is indicated byLIST:CURR:POIN? The maximum number of entries is 2950,3933 or 5900. Since the input buffer ofthe BOP has a limit of 253 characters, multiple commands are necessary to complete the full 3933entries of the list. If LIST:VOLT has any entries, an error message: -221,”Settings conflict” is posted inthe error queue. Related Commands: LIST:CURR:POIN?. (See example, Figure B-5.).B.55 [SOURce:]LIST:CURRent? QUERY LIST:CURR?Syntax: Short Form: LIST:CURR? Long Form: LIST:CURRent?Return Value: , , . . . to Description: Identifies the parameters (main channel) entered for the list. Starting at location established byLIST:QUERy, returns comma-separated list of up to 16 values indicating the main channel parametersentered. i.e., the contents of main channel locations of Table B-2. Related Commands: LIST: CURR,LIST:QUERy. If LIST:VOLT has any entries, an error message: -221,”Settings conflict” is posted in theerror queue. (See example, Figure B-5.)TABLE B-2. LIST DATA TABLELocation (DSEQ) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 . . . . . . . . . 5900Main Channel (commanded mode)LIST:CURRent or LIST:VOLTage . . . . . . . . .LIST:DWELl . . . . . . . . .