3-36 BOP HIPWR 0319123.3.12 ERROR MESSAGE EXPLANATIONSWhen a key press is not accepted, an error message is displayed at the bottom of the screen.Although recovery from most operator errors is obvious and simple, Table 3-14 lists all the errormessages along with associated explanations as to why they occurred.TABLE 3-14. ERROR MESSAGE EXPLANATIONSERROR MESSAGE EXPLANATIONGeneralMultiple Decimal places not supported Decimal key was pressed while to the right of the existing decimal point.Exceeding Maximum Allowed Value To check maximums, go to power-up screen, press %, highlight Max/Min Settings, press!.Sign does not affect Protection Limits Protection Limit field is positive or negative, numerical value does not need signEntry incomplete, Depress ENTERkeyWhen changing either the main channel or the protect channel, using the number keys, thechange must be applied to the output by pressing ENTER before moving on to change theother channel.Executing List A waveform is currently executing via remote mode. Commands to change the output arenot accepted until list is stopped (send command VOLT:MODE FIXED).Save Disabled, Request ignored Save Display Change is disabled. From power-up screen, press %, highlight passwordsettings to enable.EXTERNAL MODE enabled. MODE key does not function while Mode is being controlled externally. Press $, high-light External Mode and change to Disable.F2 Key not valid F2 only works when labeled. key was probably pressed inadvertently.Password incorrect Enter the correct password and press !. If password has been lost and can not berecovered, refer to PAR. 3.6.3.12.1 to reset to factory defaults.Setup MenuF3 - Invalid # only works when labeled. Key was probably press inadvertently.F4 - Invalid $ only works when labeled. Key was probably press inadvertently.Master/Slave MenuSeries or Parallel when notSTANDALONEMismatch between Unit type and Connection type. Automatically reverts toUnit type: Standalone, Connection Type: standalone.Calibration invalid - Multiple Unit Consult Factory.BITBUS option must be Disabled Change CIIL mode to SCPI. From power-up screen press % highlight Interface Data For-mat, press !, highlight SCPI, press $, then press $ to save for power-up, thencycle BOP off, then on.Waveform MenuExternal Reference Waveform notaccessibleReference Input must be set to Internal for waveforms to be executed. Press $ highlightReference Input, press ! highlight Internal, press $, then %.External Mode - Waveform notaccessibleExternal Mode must be disabled for waveforms to be executed. Press $ highlight Exter-nal Mode, press ! highlight Disable, press $, then %.External Limits - Waveform notaccessibleProtection Limit must be set to Internal for waveforms to be executed. Press $ highlightProtection Limit, press ! highlight Internal, press $, then %.Empty Entry - use F2 instead Empty location cannot be modified using ! Press @ to start new waveform.No Room to insert - delete a segment. No more than 10 segments are allowed in a waveform.Unable to delete segment. Try again. If still unable to delete segment, contact factory. for RMA.Only EDIT allowed on Entry. When viewing waveform, if name, count or protection levels are highlighted, press ! tomodify the setting. @ and ! are not functional with these parameters.MODE incorrect - Please Change A voltage waveform was executed while the unit was in current mode or a currentwaveform was executed while the unit was in voltage mode. Press MODE key to change tocorrect mode, press STANDBY key to set output on then press $ to run the waveform