3-14 BOP HIPWR 031912NOTE: The value entered for the main channel and the protect channel is automatically pre-vented from exceeding the preset maximum software limit (see PAR. 3.3.4).6. To program the corresponding Protect channel, press Y or U as necessary to highlight theProtect channel. Then set the value using either of the two methods described above. If theProtect Entry setting (see PAR. 3.3.3.1) is set to Independent, separate entries for the posi-tive and negative protect channel are possible. Otherwise the value entered is applied toboth positive and negative protect channels.3.3.3.1 SELECTING BIPOLAR/INDEPENDENT PROTECTION LIMITSThe BOP can be configured to show the protection limits as either a single value that applies toboth protection channels or show individual settings for positive and negative protection limits.Selecting Independent protection limits means that the positive and negative limits are dis-played (and can be modified) independently. Bipolar means that for each protection limit (volt-age or current) a single value applies to both the positive and negative limits; only one value isdisplayed and can be edited for both ± protection limits.Press % from the power-up screen to enter the General Setup menu (Figure 3-6), then high-light Max/Min Settings. Press ! to enter the Max/Min Settings submenu (Figure 3-7). (If aPassword is required, see PAR. 3.2.4.4 for instructions.) Highlight Protect Entry and press ! tochange it. Highlight Bipolar or Independent, then $ to save, or % to abort. When complete,press $ to save for power-up, or # to abort, or % to apply the changes (without saving forpower-up) and exit.Minimum (box)+Voltage Protect Min–Voltage Protect MaxCurrent mode only. Minimum (positive) setting for +Voltage Protect andmaximum (maximum negative) setting for –Voltage Protect. Values of ±Volt-age Protect between +Voltage Protect Min and –Voltage Protect Max (nearzero) are not allowed. This zone (also referred to as the minimum (box) isautomatically calculated by the BOP (see Figure 1-3).N/A N/A+Current–CurrentCurrent mode only. Positive and negative output current established bykeypad or remote command.Range (+): 0 to +Current maxRange (–): 0 to –Current minB.19+Current max–Current minCurrent mode only. Maximum (positive) and minimum (maximumnegative) current that can be set.Value (+): 0 to +I OnomValue (–): 0 to –I Onom3.3.4.1 B.21, B.22,B.25, B.23TABLE 3-4. VOLTAGE AND CURRENT PARAMETER DEFINITIONS (CONTINUED)Term DefinitionTo modifyrefer to PAR.Local Remote