BOP HIPWR 031912 1-3OUTPUT CHARACTERISTICS (Continued)Digital Programmingresolution / accuracyVoltage 14 bits / 0.03% 3% accuracy for Ext Ref Level (see PAR.3.4.3.2). Unit gain adjustable between 0 andEONOM (voltage) or IO NOM (current).Current 14 bits / 0.1%Voltage Limit 12 bits / 0.3%Current Limit 12 bits / 0.5%Digital Readbackresolution / accuracyVoltage 16 bits / 0.05% main or limit channelCurrent 16 bits / 0.1% main or limit channelSustain Outputupdate rate400 updates/Sec voltage or currentAnalog ProgrammingaccuracyVoltage 0.1% of ratingCurrent 0.1% of ratingVoltage Limit 0.3% of rating 10% to 100% of nominal range, converted todigital at 100mS rate.Current Limit 0.5% of ratingAnalog ReadbackaccuracyVoltage - Available on request: 0 to ±10V for 0 to ±nom-inal output voltage.Current 0.1% of rating 0 to ±10V for 0 to ±nominal output voltage.Digital ReadbackCharacteristicsmeasurement rate 5 msmeasurement array 64 samples voltage and currentstep change timing 40μS (default) Allows rejection of line-related ripple/noise bychanging response time for output stepchange (see PAR. B.9).Voltage stabilization involtage modesource effect 0.05% of rating min-max input voltageload effect 0.1% of rating 0-100% load currenttime effect (drift) 0.02% of rating 0.5 through 8 hourstemperature effect 0.02%/deg C of rating 0 to 50 deg Cripple and noise (2% EOmax) p-p/(0.2% EOmax) rms Includes switching noiseCurrent stabilization incurrent modesource effect 0.05% of rating min-max input voltageload effect 0.2% of rating 0-100% load voltagetime effect (drift) 0.02% of rating 0.5 through 8 hourstemperature effect 0.02%/deg C of rating 0 to 50 deg Cripple and noise 2% IOmax p-p / (0.2% IOmax) rms Includes switching noiseError sensing 0.25V or 1% of voltage rating perwire (whichever is less)Above rated output1Transient recovery involtage modemaximum excursion 5% of nominal output nominal voltage, 50% load stepRecovery time 200 μS Return within 0.1% of set voltageOutput Common Mode Voltage 300V Output to chassis groundSeries operation Master/slave Maximum of identical 3 units,up to 300V max.Parallel operation Master/slave Maximum of 5 identical unitsSeries-parallel Operation 2 series x 2 parallel3 series x 2 parallelMaster/slave for both series and parallelbranches of identical units1. Remote error sensing applies to the main voltage channel. Feedback for the ±voltage limit channels is supplied locallyfrom the power terminals. Consult factory for a remote sensing solution applicable to the voltage limit channels.TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)SPECIFICATION RATING/DESCRIPTION CONDITION