Chapter 44-16F-4-635) Open the DADF slowly, and check to make sure that A and B indicated inthe Figure is 2 mm or less. Close the DADF, and press the push switch(SW2) on the ADF controller once.- The original will be delivered to the delivery tray.F-4-64F-4-65If the Value Is Not As IndicatedAdjust the position of the manual feed registration roller.1) Remove the front cover [1].-Three screws [2] (remove)-One screw [3] (loosen)F-4-66F-4-67F-4-682) Loosen the fixing screw on the manual feed registration roller mountingplate, and slide it to the left and the right to adjust the position of the reg-istration roller.If A>0, slide the mounting plate to the right.If B>0, slide the mounting plate to the left.F-4-693) At the end of the adjustment, tighten the fixing screw on the manual feedregistration roller mounting plate.4) Set the DIP switch (SW1) on the ADF controller PCB back to its initialsetting, and mount the ADF controller cover.c. Reversal for Double-Sided Originals1) Remove the screw [1], and detach the ADF controller cover [2].F-4-702) Set the DIP switch (SW1) on the ADF controller PCB as indicated.F-4-713) Place a single sheet [1] of A4 or LTR copy paper in the original tray.J1J2J5J3 J6 J7 J8 J9 J10J16 J15J11J14IC8J13J12J4 CB1SW1DSP1SW4SW3SW2ABOriginalA 2mmB 2mmJ1J2J5J3 J6 J7 J8 J9 J10J16 J15J11J14IC8J13J12J4 CB1SW1DSP1SW4SW3SW2ScrewManual feed registration rollermounting plate[1][2]