C.2 UL and CSA Standardsu UL Standards ComplianceThe UL/cUL mark applies to products in the United States and Canada. It indicates that UL has performed product testing andevaluation, and determined that their stringent standards for product safety have been met. For a product to receive ULcertification, all components inside that product must also receive UL certification.Figure C.6 UL/cUL MarkThis drive is tested in accordance with UL standard UL508C and complies with UL requirements. The conditions describedbelow must be met to maintain compliance when using this drive in combination with other equipment:n Installation AreaDo not install the drive to an area greater than pollution degree 2 (UL standard).n Main Circuit Terminal WiringYaskawa recommends using closed-loop crimp terminals on all drive models. To maintain UL/cUL approval, UL Listedclosed-loop crimp terminals are specifically required when wiring the drive main circuit terminals on models 2A0110 to2A0415, 4A0058 to 4A1200, and 5A0041 to 5A0242. Use only the tools recommended by the terminal manufacturer forcrimping. Refer to Closed-Loop Crimp Terminal Size on page 244 for closed-loop crimp terminal recommendations.Closed-Loop Crimp Terminal RecommendationsTo maintain UL/cUL approval, UL Listed closed-loop crimp terminals are specifically required when wiring the drive maincircuit terminals on models 2A0110 to 2A0415, 4A0058 to 4A1200, and 5A0041 to 5A0242. Use only the tools recommendedby the terminal manufacturer for crimping. Yaskawa recommends crimp terminals made by JST and Tokyo DIP (or equivalent)for the insulation cap. Table C.4 matches the wire gauges and terminal screw sizes with Yaskawa-recommended crimpterminals, tools, and insulation caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gaugeand screw size for your drive model. Place orders with a Yaskawa representative or the Yaskawa sales department.Wire gauge values shown in bold italic are the recommended values. Refer to local codes for proper selections.Table C.4 Closed-Loop Crimp Terminal SizeDrive Model Wire Gauge (AWG, kcmil) ScrewSizeCrimpTerminalModel NumberTool Insulation CapModel No. Code<1>R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 Machine No. Die Jaw200 V Class2A00042A00062A00082A001014M4R2-4YA-4 AD-900TP-003 100-054-02812 R5.5-4 TP-005 100-054-029102A001214 14M4R2-4YA-4 AD-900TP-003 100-054-02812 12 R5.5-4 TP-005 100-054-029102A0018– 14M4R2-4YA-4 AD-900TP-003 100-054-02812 R5.5-4 TP-005 100-054-029102A0021 12 M4 R5.5-4 YA-4 AD-900 TP-005 100-054-029102A003010M4R5.5-4YA-4AD-900 TP-005 100-054-0298 8-4 AD-901 TP-008 100-054-0316 14-NK4 AD-902 TP-014 100-054-033C.2 UL and CSA Standards244 YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide