boards.fmA31003-H3590-S100-7-7620, 06/2012HiPath 3000/5000 V9, Service documentation 3-329Nur für den internen Gebrauch Boards for HiPath 3000Peripheral boardsHiPath 3000/5000 Manager E is used to set the signaling protocol. Settings Menu: Lines/net-working ... –> Trunks –> (double-click) Parameters –> Template Editor:● Board type = TMDID, TIEL, TMEW2● Template: the following settings are possible:– 4. E/M tieline with winkstart/delayed (= “Wink Start” protocol)– 11. E/M tieline with delayed dialing (= “Delay Dial” protocol)– 12. E/M tieline with immediate dialing (= “Immediate Start” protocol)Interface type 1A (or 5) is used in all cases.SIVAPAC connector assignment on the backplane with tie trunk traffic via interface type 1A (or5) is shown in Table 3-162.Connecting the Genius announcement deviceThe TMEW2 board may be installed on interface type 2 for connecting the Genius announce-ment device.Use HiPath 3000/5000 Manager E to configure the settings for the Genius announcement de-vice: Settings Menu: Auxiliary equipment –> Announcement.SIVAPAC connector assignment on the backplane with a Genius announcement device con-nected (interface type 2A) is shown in Table 3-163.Figure 3-112 E&M Interface Type 2SBEESGME- 48 V ESGMSBTMEW2Remote system/transmissionequipment with TMEW2- 48 V