boards.fmA31003-H3590-S100-7-7620, 06/2012HiPath 3000/5000 V9, Service documentation 3-151Nur für den internen Gebrauch Boards for HiPath 3000Peripheral boardsLED statuses and their meaningsCable and connector assignment● For connecting to the SIVAPAC connector on the backplane: Table 3-65● For connecting to the connector panels using RJ45 jacks: Table 3-66● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-67Table 3-64 SLCN (not for U.S.) - LED StatusesRed LED GreenLEDStatus ActionOff Off Board not receiving power or not plugged incorrectly.Board is out of order.Check plug contact onboard.On Off Board is receiving power and board test isin progress.Board is defective if status remains un-changed (board test unsuccessful).Replace board.Loadware loading not successfully com-pleted. Board is faulty.Replace board.Error detected on board.Board is deactivated (not applicable to er-rors detected by test loops) or board wasdeactivated using HiPath 3000/5000 Man-ager E.Check whether the boardwas deactivated using Hi-Path 3000/5000 ManagerE. If not, replace board.Flashing Off Loadware is being loaded.Off On Board test completed successfully. Board isOK (idle state).Off Flashing At least one subscriber line circuit is activat-ed.