71EnglishInformation timingSet up the informing manner for no signal ortemperature rising.During RS-232C controls:Warning or error message sent on the displayautomatically.During LAN controls:Acquire the warning or error message from thedisplay.1 Select the item with .Select the set point with .Information timingNo signal warningNo signal warning timingTemperature warningNo signal errorNo signal error timingOn5minOn10minOn[No signal warning]When set to [On], the display sends out the no signalwarning.[No signal warning timing]Set up the detecting time for no signal warning.(Range: 01 - 60, Interval: 1 minute)[No signal error]When set to [On], the display sends out the no signalerror.[No signal error timing]Set up the detecting time for no signal error.(Range: 01 - 90, Interval: 1 minute)● The warning of [No signal warning] and the errorof [No signal error] are not sent when the no signalstate is detected through any of the followingfunctions:[No signal power off], [HDMI1 power management],[HDMI2 power management], [DVI-D powermanagement], [PC power management] (see page55)● If there is no signal when [PC IN] is input, [PCpower management] is activated first and theDisplay enters the standby mode.Setting Example:[No signal warning timing]: 5 minutes[No signal error timing]: 10 minutes[PC power management]: [On] (60 seconds)Note● The [No signal error timing] cannot be set shorterthan [No signal warning timing].[Temperature warning]When set to [On], the display sends out the warningmessage.InitializationWhen both main unit buttons and remote control buttonsare disabled due to the [Button lock], [Controller userlevel] and [Controller ID function] (see page 49) settings,set all the values [Off] so that all the buttons are enabledagain.Press <- (Unit)> together with and hold for more than 5 seconds.[Shipping] is displayed and the lock is released whenit disappears.ShippingYES NO● Settings for [Button lock], [Controller user level]and [Controller ID function] will be back to [Off].