190 Menu: Menu Description TablesBATTERY SETTING1Items/Data SavedAdjustableRange RemarksPROPAC14 ½•Enable selection under BATTERYSELECT.½: Enable selection.• : Disable selection.AUTOMANUALSelect auto or manual to set the NEAREND voltage.AUTO: Set voltage automatically.MANUAL:Set voltage manually.11.0:13.8:15.0When “MANUAL” is selected in themenu above, set the NEAR END voltagein 0.1 V steps.– C U F –TRIMPAC14 ½•Enable selection under BATTERYSELECT.½: Enable selection.• : Disable selection.AUTOMANUALSelect auto or manual to set the NEAREND voltage.AUTO: Set voltage automatically.MANUAL:Set voltage manually.11.0:13.6:15.0When “MANUAL” is selected in themenu above, set the NEAR END voltagein 0.1 V steps.– C U F –HYTRON50 ½•Enable selection under BATTERYSELECT.½: Enable selection.• : Disable selection.AUTOMANUALSelect auto or manual to set the NEAREND voltage.AUTO: Set voltage automatically.MANUAL:Set voltage manually.11.0:13.5:15.0When “MANUAL” is selected in themenu above, set the NEAR END voltagein 0.1 V steps.– C U F –HYTRON140 ½•Enable selection under BATTERYSELECT.½: Enable selection.• : Disable selection.AUTOMANUALSelect auto or manual to set the NEAREND voltage.AUTO: Set voltage automatically.MANUAL:Set voltage manually.11.0:13.5:15.0When “MANUAL” is selected in themenu above, set the NEAR END voltagein 0.1 V steps.– C U F –Items/Data SavedAdjustableRange RemarksDIONIC90 ½•Enable selection under BATTERYSELECT.½: Enable selection.• : Disable selection.AUTOMANUALSelect auto or manual to set the NEAREND voltage.AUTO: Set voltage automatically.MANUAL:Set voltage manually.11.0:13.6:15.0When “MANUAL” is selected in themenu above, set the NEAR END voltagein 0.1 V steps.– C U F –DIONIC160 ½•Enable selection under BATTERYSELECT.½: Enable selection.• : Disable selection.AUTOMANUALSelect auto or manual to set the NEAREND voltage.AUTO: Set voltage automatically.MANUAL:Set voltage manually.11.0:13.2:15.0When “MANUAL” is selected in themenu above, set the NEAR END voltagein 0.1 V steps.– C U F –NP-L7 ½•Enable selection under BATTERYSELECT.½: Enable selection.• : Disable selection.AUTOMANUALSelect auto or manual to set the NEAREND voltage.AUTO: Set voltage automatically.MANUAL:Set voltage manually.11.0:13.2:15.0When “MANUAL” is selected in themenu above, set the NEAR END voltagein 0.1 V steps.– C U F –ENDURA7 ½•Enable selection under BATTERYSELECT.½: Enable selection.• : Disable selection.AUTOMANUALSelect auto or manual to set the NEAREND voltage.AUTO: Set voltage automatically.MANUAL:Set voltage manually.11.0:13.2:15.0When “MANUAL” is selected in themenu above, set the NEAR END voltagein 0.1 V steps.– C U F –