3.8 Special Wiring1612) Connect cables of the same color to each other as shown in the table below. Note thatwiring for incremental and absolute encoders is different.SignalNameColor and Wire Size ofCable with ConnectorsColor and Wire Size of50-meter ExtensionCable (DP8409179)PG5V Red AWG22 Red AWG16PG0V Black AWG22 Black AWG16FG Green/Yellow AWG22 Green/Yellow AWG16PA Blue AWG26 Blue AWG26* PA White/Blue AWG26 White/Blue AWG26PB Yellow AWG26 Yellow AWG26* PB White/Yellow AWG26 White/Yellow AWG26PC Green AWG26 Green AWG26* PC White/Green AWG26 White/Green AWG26PS Violet AWG26 Purple AWG26* PS White/Green AWG26 White/Green AWG26RESET White/Gray AWG26 White/Gray AWG26BAT Orange AWG26 Orange AWG26BAT0 White/Orange AWG26 White/Orange AWG263.8.7 Using DR2 Servopack with High Voltage Line1) DR2 Servopacks are divided into single-phase 200 V and single-phase 100 V types ac-cording to supply voltage.If, however, three-phase 400 VAC class (400 V, 440 V) power supply must be used, pre-pare the following power transformer (for single-phase). 1) 400 or 440 VAC2) 400 or 440 VAC200 VAC100 VAC3Only the absoluteencoder can beconnected.