Siemens 6SN1123-1AA00-0DA2 Configuration Manual
605.016.4 Technical data6-167© Siemens AG 2012 All Rights ReservedSIMODRIVE 611 Configuration Manual (PJU) – 02/2012 EditionTable 6-9 Technical specifications, I/R modulesInternal coolingExternal coolingHose cooling6SN11 45-6SN11 46-6SN11 45-1BA0-0BA1BB0-0BA-1BA0-0CA1BB0-0CA-1BA0-0DA1BB0-0DA1BB0-0DA1BB0-0EA1BB0-0EA1BB0-0EA1BB0-0FA1BB0-0FA1BB0-0FAInfeed/regenerativefeedbackRated power (S1)S6 powerPeak power (400 V)kWkWkW1621353647705571912)801041312)120156175Sinusoidal operation in-put currents (ACRMS)Use for dimensioning the installation, not for calculating the power!Rated current (400 V) Arms 27 60.5 92.5 134 202Squarewave operationinput currents (ACRMS)Use for dimensioning the installation, not for calculating the power!Rated current (400 V) Arms 30 67 102 149 223Use for dimensioning the installation, not for calculating the power! (calculated)Rated current (400 V)unregulated operationArms 33 74 114 165 248Connection dataVoltage (power) Vrms refer to Chapter C.1.3, Table 3.5Voltage (electronics) V refer to Chapter C.1.3, Table 3.5Power supply Vrms At the DC link with 600/625/680 V DC or supplied in parallel, AC and DC con-nection or DC connection only.Frequency Hz 50 to 60 10%Connection cross–sec-tionmm2 Max. 16 Max. 50 Max. 95 Max. 95 Max. 150Output voltage V regulated: 600/625; unregulated: 490...680 (line supply–dependent)Module width mm 100 200 300 300 300Type of coolingInternal cooling(volumetric flow rate) m3/hFan56Fan112Fan112Built–on fan4003)Built–on fan1)4003)(volumetric flow rate)External cooling1)Hose coolingm /h 56Fan–112Fan–Mounting frame (Bestell-Nr. 6SN1162–0BA04–0EA) with fan assembly and built–onfan (6SN1162–0BA02–0AA2Hose cooling – – Kit for hose cooling with fanLossesInternal coolingExternal coolingHose coolingWW (int./ext.)W (int./ext.)32050/270–58550/535–745115/630115/6301280190/1090190/10901950290/1660290/1660Efficiency η 0.97 0.97 0.97 0.97 0.97WeightInternal coolingExternal coolingHose coolingkgkgkg10.510.5–15.515.5–2626262626262929291) For a module width of 300 mm with external cooling, mounting frames are required that must be ordered separately.The fan assembly required to mount the built–on fan is included in the scope of supply of the mounting frame.The built–on fan must be ordered separately! Mounting frames are also available for smaller module widths. However,these are not required if openings are cut out in the rear cabinet panel for the module heatsinks as shown in thisConfiguration Manual.2) External power supply for main contactor control required (see Chapter 6.2.5).3) ) Must be separately ordered: Mounted fan, 6SN1162–0BA02–0AA24) See the diagram with pipe cooling in Chapter 2.7.1, Fig. 2-76 Infeed Modules02.12 |
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved