Siemens 6SN1123-1AA00-0DA2 Configuration Manual
605.016.2 Interface overview6-149© Siemens AG 2012 All Rights ReservedSIMODRIVE 611 Configuration Manual (PJU) – 02/2012 EditionTable 6-1 Interface description for NE modules, continuedTerm.No.Terminals pro-vided on3)Max. cross–section10)Typ. voltage/limit valuesfor Vn 400 VType1)FunctionDesigna-tion7454410152)R6)X141X141X141X141X141X141P24P15N15N24MRESETOOOOOI+20,4...28,8 V/50 mA+15 V/10 mA–15 V/10 mA–20,4...28,8 V/50 mA0 VKL15/RE = 10 kΩ1.5 mm21.5 mm21.5 mm21.5 mm21.5 mm21.5 mm2I/R, UI, monitor-ing module92)8)1122)X161X161Enable voltageSetting–up operation/normal operationOI+24 V+21 V...30 V/RE = 1.5 kΩ1.5 mm21.5 mm2 I/R, UI, monitor-ing module482)1117)2137)1137)X161X161X161X161Contactor controlSignaling contacts,line contactorIINCNO+13 V...30 V/RE = 1.5 kΩ+30 V/1 A (111–113)1–ph. 250 V AC/50 V DC/2 A max17 V DC/3 mA min1.5 mm21.5 mm21.5 mm21.5 mm2 max.cable length, 30 mI/R, UINS1NS2X171X171Coil contact forline supply, pre–charging contactorOI+24 V 1.5 mm21.5 mm2 I/R, UIAS112)AS212)X172X172Signaling contactStart inhibit (T.112)INCmax. 250 V/1 A AC13) /30 V/2 A DC1.5 mm21.5 mm2 I/R1) I = input; O = output; NC = NC contact; NO = NO contact; (for signal, NO = high; NC = low)P = only for PELV voltage; S = only for SELV voltage2) Term. 19 is the reference ground (connected through 10 k to the general reference ground X131/T.15 inside the module)Terminal 15 must not be connected to PE, to terminal 19 or to external voltage sources.Terminal 19 can be connected with X131.The terminal may be used only for enabling the associated drive group.3) I/R = infeed/regenerative feedback module; UI = unregulated infeed; MM = monitoring module;PR = pulsed resistor module4) The first data applies with pin–type cable lug. The second data is used for finely–stranded cable without end sleeve.5) The grounding clip is used to ground the DC link M600 busbar through 100 kΩ (must be closed and must not be closedif RCCBs are used, see also Chapter 8.1;the grounding clip must be opened if the system is subject to a high–voltage test).6) RESET = resets the fault memory, edge–triggered for the complete drive group (terminal ”R” Terminal 15 = RESET)7) Terminals 111–213, positively–driven opening contacts (for I/R 16 kW and UI 10 kW, only from Order No. [MLFB]:6SN114–101–0)Terminals 111–113 NO contact not positively–drivenFor I/R 16 kW (from version E) and UI 10 kW (from version F) the following apply:Terminals 111–213, positively–driven opening contacts (series circuit of NC contact, main contactor and NC contact,pre–charging contactor)Terminals 111–113, positively–driven NO contacts8) Max. current load of terminal 9 with respect to terminal 19: 0.5 A.9) Only for UI 28 kW10) For UL certification, only use copper cables dimensioned for an operating temperature 60 ! "# $12) When the AS1/AS2 contacts are connected in series a contact resistance of approx. 0.20 Ohm must be taken intoconsideration over the lifetime of the contacts. For a 24 V switching voltage, from experience, a seriescircuit of up to five contacts can be used without any problems due to the non–linear contact characteristics.13) In accordance with EN 60204–1 (machine safety), control transformers must be used for AC control voltages.! WarningIn order to avoid damage to the infeed circuit of the NE modules, whencontrolling/energizing terminal 50 at X221 (PR module, DC link fast discharge)it should be ensured that terminal 48 of the NE module is de–energized (themodule is then electrically isolated from the line supply). The feedback signalcontacts from the main contactor of the NE module (X161 term. 111, term. 113,term. 213) must be evaluated.6 Infeed Modules02.12 |
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved