505.015.2 Operating modes5-123© Siemens AG 2012 All Rights ReservedSIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition5.2 Operating modes with synchronous motors (FD)– 1FT6, 1FK6 and 1FK7 servo motors– 1FW6 built–in torque motors (direct drives)– 1FN linear motors with induction motors (MSD–IM)– 1PH main spindle motors– 1PM hollowshaft motors for main spindle drives (direct drives)– standard induction motors (sensorless)If IM operation is selected, only inverter pulse frequencies of4 kHz and 8 kHz are permissible. with synchronous motors (MSD–SRM)– 1FE1 main spindle motors– 2SP1 motor spindleNoteFor the MSD–SRM operating mode (high–speed MSD synchronousapplications), inverter pulse frequencies are set that differ from the ratedfrequencies. This consequently ensures an optimum ratio between the inverterpulse frequency and the output frequency.The derating resulting from this should be taken into account when selectingthe power module.The frequencies relevant when engineering the system should be appropriatelytaken from the following documentation.Reader’s noteTechnical data and ordering data, refer toReference: /PJFE/ Configuration Manual, 1FE1 Synchronous Built–inMotors/BU/ Catalog NC 60 2004/PMS/ Configuration Manual ECO Motor Spindles for2SP1 Main Spindle DrivesWEISS GmbH/Operating Instructions ECO Spindle Units Type 2SP1...Feed drivesMain spindledrives5 Power Modules10.0411.05 |