iDCS 500 PROGRAMMINGTECHNICAL MANUAL PART 2 NOVEMBER 2001MMC: 115 SET PROGRAMMED MESSAGEDESCRIPTION:Allows the system administrator to set a programmed message at any or allkeysets. There are 20 messages available on a iDCS 500-M system and 30 on aiDCS 500-L system. The first ten are pre-programmed and the remaining entries canbe customized in MMC 715, Programmed Station Message. On a iDCS 500-Lsystem messages 26-30 are special in that a five digit extender can be added for adate and time.PROGRAM KEYSUP & DOWN Used to scroll through optionsKEYPAD Used to enter selectionsSOFT KEYS Move cursor left and rightSPK Used to store data and advance to next MMCHOLD Used to clear previous entryANS/RLS Used to select ALLACTION DISPLAY1. Press TRSF 115Display shows[201] PGMMSG(00)CANCEL PGM MSG2. Dial station number (e.g., 205)OR[205] PGMMSG(00)CANCEL PGM MSGPress UP or DOWN to select station andpress RIGHT soft key to move cursorORPress ANS/RLS to select All[ALL] PGMMSG(??)3. Dial an entry number to select messagenumber, e.g., 05[205] PGMMSG(05)PAGE MEORPress UP or DOWN to select messagePress RIGHT soft key to return to step 24. Press TRSF to store and exitORPress SPK to store and advance to next MMC