iDCS 500 PROGRAMMINGTECHNICAL MANUAL PART 2 AUGUST 2003MMC: 851ALMCODE ALARM DEFINITIONMJD17 RAM Error An error has occurred in the TEPRI or BRI card RAM.Alarm data = Cabinet, Slot (Cx-Syy)MJD18 E1 Restart The E1 card has restarted.Alarm data = Cabinet, Slot (Cx-Syy)MJD19 PRI Restart The PRI card has restarted.Alarm data = Cabinet, Slot (Cx-Syy)MJD20 BRI Restart The BRI card has restarted.Alarm data = Cabinet, Slot (Cx-Syy)MJD21 PCM Loss Loss of PCM coding on a digital facility.Alarm data = Cabinet, Slot (Cx-Syy)MJD22 PCM Recovery Recovery of PCM coding on a digital facility.Alarm data = Cabinet, Slot (Cx-Syy)MNF01 Card OutA circuit card mounted in a universal slot has been removedfrom service or is not recognized by the system.Alarm data = Cabinet, Slot (Cx-Syy)MNF02 Card InA circuit card mounted in a universal slot has been removedfrom service.Alarm data = Cabinet, Slot (Cx-Syy)MNF03 IPC Error Inter processor communication error has occurred.Alarm data = Cabinet, Slot (Cx-Syy)MNF04 Trunk FaultOut of service trunk detected via loop detect. Internal CODECtest.Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF05 Trunk RecoveryOut of service trunk detected via loop detected as out of serviceis now operational.Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF06 Trunk DisconnectOut of service trunk detected via seizure of trunk. Externalseizure test.Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF07 Trunk ConnectOut of service trunk recovered via seizure of trunk Externalseizure test.Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)MNF08 SIO TxQ SIO Tx Queue full error has occurred in the MCP.Alarm data = SIO number (SIO:x)