GX-Series Control Panel Installation and Setup Guide6-1152 = Setting LogicThe Setting Logic option restricts a group from setting by determining which other groups must be setbefore it can set. For example, group 1 may be prohibited for setting (arming) unless groups 3, 7 arealready set. The Setting Logic is individually defined for each group.Programming Setting LogicOn selecting the Setting Logic option, group 1 is displayed. Use the A> or keys to move to therequired group or directly select it by pressing the required group number; press the ent key to accessthe group. On selecting the group, the current Setting Logic details are displayed:• S below a group means that it must be set to allow the selected group to set• a dash (–) below the group indicates that the set status of this group is not important.Toggle the status between S and – by pressing the number key. When the required setting logic patternhas been defined press the ent key to accept the programming and return to the previous menu type.Multi-group SystemsThe larger GX-Series panels have 32 groups; these are displayed on the keypad in block of eight groups,subdivided into A, B, C and D:Group Block Physical GroupsA1-8 1-8B1-8 9-16C1-8 17-24D1-8 25-32Table 6-28. GroupsUse the A> or key to move between the group blocks; press keys 1 – 8 to toggle the Setting Logic for therelevant groups in each block.Setting Logic OperationIf Setting Logic has been assigned to a group, the set status of the groups must satisfy the conditionsdefined in the option to permit the group to set. If the Setting Logic conditions are not satisfied, then thegroup cannot set. If multiple groups are being set simultaneously, but one group is restricted due to theprogrammed Setting Logic, the remainder of the groups set. The restricted group does not set; there is nowarning or indication given.If the programmed Setting Logic results in none of the selected groups being allowed to set, a warningmessage is displayed on the keypad.GX-083-V0