GX-Series Control Panel Installation and Setup Guide6-53Option 52 – Program ZonesThis option is used by the engineer to modify the programming of the zones on the system. The option alsoallows the attributes of the zone to be changed. The programmable options are shown in the table thatfollows:Attributes Description1 Function assign zone type2 Descriptor 16 character (max.) alpha-numeric description3 Chime enabled = momentarily chime effect if zone opened while unset (disarmed)4 Omit enabled = zone can be omitted (bypassed)5 Part enabled = zone included in part setting (part arming) of system6 Resp. Time Modify circuit debounce time7 Custom SIA Select SIA event8 Activity Mon. Selects criteria for zone activity checking9 Res. Select Selects resistance range for zone10 Group assign zone to a single group on the systemNote: Groups only appear if the Group option is enabled (refer to option 63.1 =OPTIONS.Groups).Table 6-13. Zone AttributesSelecting ZonesOn entering the option, the first zone on the system is displayed; the zone address, function and groupassigned are displayed on the top line, the descriptor is displayed on the bottom line. Pressing the # keytoggles the descriptor to reveal the status of the chime, omit and part attributes. If the attribute is enabled,the initial attribute letter is displayed, if it is disabled, a dash (–) is shown. For example, chime, part andomit enabled display as COP, if omit is disabled the display would be C – P.From the display of the first zone, any zone on the system can be displayed by pressing the A> or keys orby entering the address of a specific zone.The zone is selected for programming by pressing the ent key; the first zone programming attribute1=Function is displayed.AttributesThe attributes can be stepped through by pressing the A> or keys or directly selected by pressing theattribute number (1–8). Once the required attribute is on display, press the ent key to gain access formodification.Once the attribute has been assigned press the ent key to save the programming and return to the attributeselection level.Pressing the esc key at any time when assigning attributes 1 and 3–10 to a zone aborts the programmingand returns to the attribute selection level. Pressing the esc key when assigning a descriptor to a zone savesthe assigned alphanumeric text and returns to the attribute selection level.1 = FunctionEntering the Function attribute displays the address and the current function of the selected zone alongwith the zone function reference number. The zone functions can be stepped through, forwards orbackwards, using the A> and keys. Alternatively a zone function can be directly selected by entering thezone function reference number, for example, entering the 19 displays zone function 19 = FIRE.Once the required zone function is displayed, it is assigned to the zone by pressing the ent key.