381Chapter 10: TroubleshootingReported Event Corrective ActionRedundancy Check isstoppedRedundancy Check stopped because of userintervention, schedule or the logical drive was deletedor went critical or offline. See page 384.Redundancy Check isaborted due to internalerrorSystem resources are low. Reduce system load orrestart the ASUS Storage. See page 130 (ASUSStorage Management) or page 280 (CLU).Redundancy Checkencountered inconsistentblock(s)Check the logical drive’s inconsistent block table. Seepage 167. Rebuild the disk array if necessary. Seepage 149 (ASUS Storage Management) or page 225(CLU).Redundancy Check taskis queuedRedundancy Check has been set manually or byschedule.Redundancy Check taskis stopped internallyThe logical drive is offline. See page 384.ResourceResource is NOTavailableSystem resources are low. Reduce system load orrestart the ASUS Storage. See page 130 (ASUSStorage Management) or page 280 (CLU).Spare CheckSpare check started onthe given spare driveResult of settings or user action. Normal.Spare check completedsuccessfully on the givenspare driveNormal.Spare DrivesPhysical disk assigned asglobal spareResult of settings or user action. Normal.Physical disk is no longerassigned as global spareResult of settings or user action. Normal.Global Spare has beendeletedResult of settings or user action. Normal.Physical disk assigned asdedicated spareResult of settings or user action. Normal.Physical disk is no longerassigned as dedicatedspareResult of settings or user action. Normal.