217Chapter 6: Management with the CLUManaging the EnclosureEnclosure Management includes the following functions:• Viewing Enclosure Information (page 217)• Viewing Power Supply Status (page 217)• Locating a Power Supply (page 218)• Viewing Cooling Unit Status (page 218)• Viewing Voltage Sensor Status (page 218)• Viewing Temperature Sensor Status (page 218)• Setting Temperature Thresholds (page 219)• Checking the Batteries (page 219)• Reconditioning a Battery (page 220)• Locating an Enclosure (page 220)• Viewing Enclosure Topology (page 221)Viewing Enclosure InformationEnclosure Management includes information, status, settings and location. Toaccess Enclosure Management:1. From the Main Menu, highlight Subsystem Management and press Enter.2. Highlight Enclosure Management and press Enter.To access FPU VPD information (vital product data on field replaceable units),highlight FPU VPD Information and press Enter.This function lists the battery backup unit and backplane.Viewing Power Supply StatusTo view the status of the power supplies:1. From the Main Menu, highlight Subsystem Management and press Enter.2. Highlight Enclosure Management and press Enter.3. Highlight Power Supply Units and press Enter.The screen displays the status of ASUS Storage’s power supply. If anystatus differs from Powered On and Functional, there is a power supplymalfunction. See ―Replacing a Power Supply‖ on page 311.