7628-0724/026.4 Carbonation SystemThe carbonating system consists of the following components:• Electrode - When the water level in the carbonator tank falls below the tip, the liquidlevel control turns on the pump motor for 5.5 seconds. If the water level does not reachthe tip, the motor continues to run in 5.5 second intervals until the water touches thetip. Once the water reaches the tip, the motor will stop running at the end of the 5.5second interval. The black wire and the green (ground) wire complete the circuit insidethe tank.• Picture Frame Carbonator Tank (embedded in cold plate - 131 oz capacity)• CO2 Check Valve - Prevents carbonated water from backing into the CO2 system.• Backflow Preventor - Prevents carbonated water from backing into building's watersupply.• Relief Valve - Vents the carbonator when pressure exceeds 240 psig.Carbonator Pump - Consists of the following components:• Pump Motor - Standard 1/3 hp motor• Water Pump - Standard 100 GPH 250 psig bypass• Liquid Level Control - Operates as a timer. When liquid level drops below the probetip, the control turns on the carbonator pump motor for 5.5 seconds and then shuts off.The liquid level control will time out after 3 minutes of cycling on and off if probe fails. Alight on the liquid level control will blink as well.