15 28-0724/021.5 LEVELINg THE DISPENSERIn order to facilitate proper dispenser drainage and carbonation, ensure that thedispenser is level, front to back and side to side. Place a level on the top of the rearedge of the dispenser. The bubble must settle between the level lines. Repeat thisprocedure for the remaining three sides. Level unit if necessary.1.6 INSTALLINg THE DISPENSER1. Remove cup rest, drip tray (if used), splash plate, and top cover.2. Remove cover plate at rear of unit if not a through-the-counter installation.3. Connect soda and water supply lines to 3/8“ barb fittings at the front of the unit.NOTE: If the unit is not installed on legs, all connections to the inlets on the coldplate will need to have 3/8” 90° splices as the beverage tubing will kink if you tryto run the tubing directly into the fittings on the cold plate.1.7 CONNECTINg WATERConnect water as follows using 1/2" black line:1. From source to booster (if needed).2. From booster to filter.3. From filter to water regulator on pump platform.4. From pump outlet to soda water inlet on dispenser. NOTE: The line from the pumpto the dispenser can be 3/8”.5. Splice “T” into line within 1 to 2 feet of water source (after booster and filters) in backroom if possible.6. Connect plain water line to dispenser. NOTE: Run 1/2" line within 1 or 2 feet ofdispenser. Splice down to 3/8” to connect to dispenser.7. Install shut-offs on water line prior to carbonator pump and CO2 line prior todispenser. NOTE: All water lines should be black.