B-13DNW-A75/A75P625/50ITEM Factory setting Current Bank 1 Bank 2 Bank 3 Bank 4311: ANALOG AUDIO EDIT PRESET REPLACE FOR CH1 CH 1312: ANALOG AUDIO EDIT PRESET REPLACE FOR CH2 CH 2313: ANALOG AUDIO EDIT PRESET REPLACE FOR CH3 NODEF314: ANALOG AUDIO EDIT PRESET REPLACE FOR CH4 NODEF317: AUDIO EDIT MODE CROSS318: EDIT RETRY ON319: PREREAD SELECT A/V320: DIGITAL AUDIO PB PROCESS ON EDIT POINT FADE326: AUTOMATIC IN ENTRY AFTER AUTO EDIT OFF334: EE REFERENCE CONTROL NORMITEM-400 series: Preroll parameterITEM Factory setting Current Bank 1 Bank 2 Bank 3 Bank 4401: FUNCTION MODE AFTER CUE-UP STOP402: TIME REFERENCE FOR PREROLL CTL403: AUTOMATIC PREROLL REFERENCE ENTRY DIS405: CUE-UP BY CTL CAPITEM-500 series: Tape protection parameterITEM Factory setting Current Bank 1 Bank 2 Bank 3 Bank 4501: STILL TIMER 8M502: TAPE PROTECTION MODE FROM SEARCH STEP503: TAPE PROTECTION MODE FROM STOP STDBY504: DRUM ROTATION IN STANDBY OFF OFF505: STILL TENSION NORMITEM-600 series: Time code generator parameterITEM Factory setting Current Bank 1 Bank 2 Bank 3 Bank 4601: VITC POSITION SEL-1 19H602: VITC POSITION SEL-2 21H603*: ID CODE PRESET OFF _ _ _ _ _604: ID CODE SW OFF605: TCG REGEN MODE TC&UB606: TC OUTPUT SIGNAL IN REGEN MODE TAPE607: U-BIT BINARY GROUP FLAG 000608: PHASE CORRECTION OFF609: TCG CF FLAG OFF610: REGEN CONTROL MODE AS&IN616: SDTI-CP OUTPUT LTC OVERRIDE DIS(When BKNW-124 is used only.)*: ITEM-603 is no relation with Bank.