4-48 DNW-A75/A75PA001 : S REEL FG DUTYA002 : T REEL FG DUTYA003 : CAPSTAN FG DUTYA004 : S REEL OFFSET/FRICTIONA005 : T REEL OFFSET/FRICTIONA006 : S REEL TORQUEA007 : T REEL TORQUEA008 : S/T TENSION OFFSETThese menus are used to perform the automatic adjust-ments below.A001 : S reel FG duty adjustmentA002 : T reel FG duty adjustmentA003 : Capstan FG duty adjustmentA004 : S reel offset/friction adjustmentA005 : T reel offset/friction adjustmentA006 : S reel torque adjustmentA007 : T reel torque adjustmentA008 : S/T tension offset adjustmentTo execute the automatic adjustments(1) Press the SET button to initiate the automatic adjust-ment.. The execution time is about fifteen seconds forA001 to A003 and about twenty seconds for others.. During the adjustment, the adjustment menu name inexecution and a message “ADJUSTING......” will bedisplayed on only the superimposed display.(2) Check the adjustment result.. On completing the automatic adjustment, a message“ADJUST COMPLETE” will be displayed.If the automatic adjustment fails, a message “#ADJUST INCOMPLETE #” will be displayed. Inthis case, refer to the “For Automatic AdjustmentFailure (A000 to A011)” on page 4-51.(3) To exit the menu, press the MENU button once.(4) To save the adjustment data into the NV-RAM of aservo system, execute the SAVE SERVO ADJUSTDATA in A012 : NV-RAM CONTROL menu.Example of display and operationExample of A001 : S REEL FG DUTY4-2. TAPE Maintenance Mode (M0)4-2-7. SERVO ADJUST Mode (A00-01)SERVO ADJUSTA001:S REEL FG DUTYSERVO ADJUSTA001:S REEL FG DUTYADJUSTING......SERVO ADJUSTA001:S REEL FG DUTYADJUST COMPLETE(1) 00[SET]* A012:NV-RAM CONTROLSERVO ADJUSTA001:S REEL FG DUTY# ADJUST INCOMPLETE ## S REEL TROUBLE #(2)(3)(4)000Check[MENU]Data saveEx.: When failing the automatic adjustment