4-91DNW-A75/A75PM392 : NV-RAM CONTROLThis menu is used to save the input/output data set in the50 PIN DATA ASSIGN mode into the NV-RAM.The current setup data can return to the former saved databefore the change when executing ALL DATA PREVI-OUS without saving the setup data into the NV-RAM.nWhen the power is turned off without saving the changeddata, the setup data returns to the former saved data.To execute the menu(1) Turn the search dial to set the * mark on the superim-posed display as described below.To save the setup data after changing:8 “SAVE ALL DATA”To return the setup data before changing:8 “ALL DATA PREVIOUS”To return the setup data to factory setting, and savethat data:8 “RESET ALL DATA”(2) Press the SET button.. On pressing it, the data transmission is initiated.. On the superimposed display, a message “Saving ...”or “Loading ...” will be displayed.In the time data display area, a message “SAVING”or “LOADING” will be displayed.(3) Check to see that the data transmission is completed.. On completing the data transmission:On the superimposed display, a message “SaveComplete.” or “Load Complete” will be displayed.In the time data display area, a message “SAVING”or “LOADING” will be displayed.(4) To exit the menu, press the MENU button once.Example of display and operation4-4. OTHERS CHECK Mode (M3)4-4-8. 50PIN DATA ASSIGN Mode (M39)50PIN DATA ASSIGNM392:NV-RAM CONTOROLNO OPERATIONSAVE ALL DATAALL DATA PREVIOUSRESET ALL DATA*(1) 0 DIAL (2)(2) 0 [SET]50PIN DATA ASSIGNM392:NV-RAM CONTOROLNO OPERATIONSAVE ALL DATAALL DATA PREVIOUSRESET ALL DATA***050PIN DATA ASSIGNM392:NV-RAM CONTOROLNO OPERATIONSAVE ALL DATAALL DATA PREVIOUSRESET ALL DATASaving......(3)(4)00Check[MENU]50PIN DATA ASSIGNM392:NV-RAM CONTOROLNO OPERATIONSAVE ALL DATAALL DATA PREVIOUSRESET ALL DATASave Completed