Analog-to-Digital Converter/Brownout Detector LH75400/01/10/11 (Preliminary) User’s Guide23-12 6/25/0323.3.2.3 Results RegisterRR is the Results Register. This Read Only register is a 16-entry × 16-bit wide FIFO thatholds 10-bit ADC output and the 4-bit tag number from the Control Bank State Machine.The read-and-write pointer specifies the FIFO entry to access when a Read or Write isrequested. When the FIFO is full, further data writes are temporarily blocked until at leastone location is available for the write. Reading from RR removes an entry from the FirstOut end of the result FIFO.Table 23-7. RR RegisterBIT 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16FIELD ///RESET 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0RW R R R R R R R R R R R R R R R RBIT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0FIELD BITRES /// CBTAGRESET 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0RW R R R R R R R R R R R R R R R RADDR 0xFFFC3000 + 0x08Table 23-8. RR Register DefinitionsBIT NAME DESCRIPTION31:16 /// Reserved Read as zero.15:6 BITRES ADC Converter Output 10-bit digital output of the ADC converter.5:4 /// Reserved Read as zero.3:0 CBTAGControl Bank Tag Entry number (HWCTRLBxx or LWCTRLBxx) of theControl bank. The entry number (x) ranges from 0 to 15, corresponding to theconversion associated with the bit result.