2.8 [2] System398 PC Programming ManualValue RangeMax. 4 digits (consisting of 0–9, *, and #)Maintenance Console Location2.8.8 [2-6-1] Numbering Plan—MainProgramming Manual References2.8.17 [2-9] System Options—Option 4—Busy Out—Busy Out for Analogue COFeature Guide References1.5.4.6 Trunk Busy OutSimplified Voice Message Access (KX-TDA30 only)Specifies the feature number used to access the SVM feature to record, listen to and deletemessages.Value RangeMax. 4 digits (consisting of 0–9, *, and #)Maintenance Console Location2.8.8 [2-6-1] Numbering Plan—MainProgramming Manual References2.10.9 [4-1-7] Wired Extension—Simplified Voice Message (KX-TDA30 only)2.10.16 [4-2-5] Portable Station—Simplified Voice Message (KX-TDA30 only)Feature Guide References1.17.8 Built-in Simplified Voice Message (SVM)Other PBX ExtensionOther PBX extension numbers can be used to easily call extensions connected to PBXs at differentlocations in a TIE line network. The leading numbers of all PBXs in the network that will be calledshould be entered in this table. A maximum of 16 leading numbers can be programmed.DialSpecifies the leading extension number of the other PBX.Value RangeMax. 3 digits (consisting of 0–9, *, and #)Maintenance Console Location2.8.8 [2-6-1] Numbering Plan—MainProgramming Manual References2.15.1 [9-1] TIE Table—Leading Number