60Error messages (continued)If “T&S&M” is selected in the menu No. 008 DISPLAY SEL, a message appears in the modedisplay whenever a warning orerror occurs. When multiple events occur, the event with the highest priority is displayed.UMID information displayThis is displayed when UMID information is present on the input signal in EE mode.This lamp lights during tape playback when UMID information has been recorded on the tape. “NO-INFO” is displayed whenthere is no UMID information.Priority Display DescriptionHighLowError messages(See error message table)When an operational malfunction has occurred in the unit, the error number flashes and theerror message is indicated on the counter display.INT SGWhen SG has been selected as the input signal by the INPUT SELECT button, the “INT SG”display will appear for the first two seconds at the start of operation (EE mode) when the RECbutton is pressed.NO INPUTIf there are no input signals--with the exception of the analog audio signals-- supplied to theconnectors selected by the INPUT SELECT button, the “NO INPUT” display will appear for thefirst two seconds at the start of operation (EE mode) when the REC button is pressed.Warning messages(See error message table)When a warning occurs in this unit, the error number and warning message are indicated on thecounter display. When multiple warnings occur, the warning with the highest priority isdisplayed.Display DescriptionMATNO Material numberCOPY Instance number (No. of copies)OWNR Country, organization, userPOSReception status from GPS satellites when recording spatial coordinates(height above sea level, longitude and latitude):HOLD: No reception from any satellite2D: Reception possible, but number of satellites is insufficient. Heightabove sea level will not be accurate.3D: Good receptionDATE DateTIME UTC (Coordinated Universal Time) and time difference with UTC