Configuring Your Server 4-23ServerThe Server menu appears if you move the cursor to "Server."See the table below for the items.Option Parameter Description Your SettingAssert NMI onSERRDisabled[Enabled]Indicates whether PCI SERR issupported or not.Post Error Pause Disabled[Enabled]Indicates whether POST is aborted onceat the end of POST if an error occursduring the execution of POST.AC LINK Stay Off[Last State]Power OnIndicates the AC LINK function. Showsthe state of the power of the server.[ ]: Factory-setIMPORTANT: To power on the server from the UPS (Uninterruptible PowerSupply), select [Server] - [AC Link] - [Power On]. If the server is connected to the UPS, set at least 10 seconds delay inthe power-on schedule.The table below shows the operation when the AC power to the server is turn off once and then onagain, depending on the setting of "AC LINK."Setting of AC LINKSystem status before AC power off Stay Off Last State Power OnOperating Off On OnAborting (DC power being off also) Off Off OnForced shutdown Off Off On* Press the power switch continuously for four seconds or longer. This forcibly turns off thepower.