593. Common cathode connection (to controllers that support valid high level output)Fig. 7-4 Common cathode connection (to controllers that support valid high level output)7.1.2 Parameters for Pulse Control Mode1. Parameters for electronic gear ratioTable 7-1 Parameters for electronic gear ratioNumericDisplayVariable Name Meaning Default Value Ranged3.34 Gear_Factor Numerator of electronicgear 0 in mode -41000 -32767~32767d3.35 Gear_Divider Denominator of electronicgear 0 in mode -41000 1~32767Parameters for electronic gear ratio are used to set the numerator and denominator of electronic gears whenthe driver operates in mode -4.Command pulse input Command pulse outputF1 F2Namely: F2=DividerGearFactorGear__ * F1If the electronic gear ratio is 1:1, 10000 pulses are inputted externally (the resolution of encoders is 2500PPR, quadruple), and the motor turns a circle. If the electronic gear ratio is 2:1, 10000 pulses are inputtedexternally, and the motor turns two circles.2. Parameters for pulse mode selectionTable 7-2 Parameters for pulse mode selectionNumeric Variable Name Meaning Default RangeDividerGearFactorGear__